Fetal Electrophysiologic Abnormalities in High-Risk Pregnancies Associated With Fetal Demise
![]() |
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Know the risks and potential benefits of clinical studies and talk to your health care provider before participating. Read our disclaimer for details. |
ClinicalTrials.gov Identifier: NCT03775954 |
Recruitment Status :
Recruiting
First Posted : December 14, 2018
Last Update Posted : March 20, 2023
|
Tracking Information | |||||||||
---|---|---|---|---|---|---|---|---|---|
First Submitted Date | October 24, 2018 | ||||||||
First Posted Date | December 14, 2018 | ||||||||
Last Update Posted Date | March 20, 2023 | ||||||||
Actual Study Start Date | July 1, 2018 | ||||||||
Estimated Primary Completion Date | April 30, 2023 (Final data collection date for primary outcome measure) | ||||||||
Current Primary Outcome Measures |
|
||||||||
Original Primary Outcome Measures |
|
||||||||
Change History | |||||||||
Current Secondary Outcome Measures |
|
||||||||
Original Secondary Outcome Measures |
|
||||||||
Current Other Pre-specified Outcome Measures | Not Provided | ||||||||
Original Other Pre-specified Outcome Measures | Not Provided | ||||||||
Descriptive Information | |||||||||
Brief Title | Fetal Electrophysiologic Abnormalities in High-Risk Pregnancies Associated With Fetal Demise | ||||||||
Official Title | Fetal Electrophysiologic Abnormalities in High-risk Pregnancies Associated With Fetal Demise | ||||||||
Brief Summary | Each year world-wide, 2.5 million fetuses die unexpectedly in the last half of pregnancy, 25,000 in the United States, making fetal demise ten-times more common than Sudden Infant Death Syndrome. This study will apply a novel type of non-invasive monitoring, called fetal magnetocardiography (fMCG) used thus far to successfully evaluate fetal arrhythmias, in order to discover potential hidden electrophysiologic abnormalities that could lead to fetal demise in five high-risk pregnancy conditions associated with fetal demise. | ||||||||
Detailed Description | Fetal demise occurs in over 25,000 pregnancies annually in the US and over 2.5 million in pregnancies worldwide. Certain maternal-fetal-placental abnormalities can have a high risk of fetal demise. Despite advances in fetal surveillance with ultrasound and cardiotocography, the reduction in fetal mortality lags behind that of the neonate and has shown little decline in the past decade. This suggests that the type of fetal monitoring used may not be assessing the correct indicators of mortality. In all other age groups, electrocardiographic (ECG) and continuous heart rate (HR) monitoring are used in every intensive care unit or emergency setting; however, for the fetus, the ECG signal is nearly completely insulated and inaccessible. As the result, indirect assessment of cardiac rhythm is obtained using echocardiography/Doppler, but echo/Doppler does not have the precision to assess beat-to-beat HR variability and cannot assess cardiac repolarization at all. In this study, the investigators will evaluate five high risk conditions (major congenital heart disease in the fetus, fetal hydrops (immune and non-immune), monochorionic twin pregnancy, prior pregnancy ending in fetal demise, and gastroschisis) using Fetal Magnetocardiography (fMCG)which detects the natural magnetic signals accompanying the cardiac electrical signal. It is a new, safe, and non-invasive recording technique that has been performed for several decades, and has recently gained FDA approval for recording cardiac signals at all ages, including in the fetus. Normative data has been obtained at the University of Wisconsin - Madison Biomagnetism Laboratory in 257 healthy fetuses by co-investigator Ronald T. Wakai, PhD. Over 550 serious fetal arrhythmias have been evaluated to date. Fetal MCG has proven invaluable in fetal Long QT Syndrome in identifying markers for risk of sudden death such as Torsades de Pointes Ventricular Tachycardia (VT), T wave alternans, 2nd degree AV block, and QTc>590 ms. To date, fMCG has not been systematically applied to diseases that are not associated with recognizable arrhythmias because the impact of silent conduction and repolarization defects has been underappreciated. In this grant, the investigators hypothesize that beat-to-beat fetal heart rate variability abnormalities and electrophysiologic abnormalities, are present in five high risk maternal-fetal-placental conditions associated with fetal demise. The study will determine which electrophysiologic abnormalities precede fetal demise or adverse pregnancy outcome. Preliminary findings in healthy normal subjects in RO1HL063174 (Wakai) show repolarization abnormalities in up to 5%, and some of these are modifiable once recognized. Two hundred pregnant subjects will be studied over a 5 year period both at referral (~20-27 weeks GA) and later in pregnancy at 30-37 weeks GA. fMCG results will be compared to neonatal ECG (nECG) obtained at 0-4 weeks of life. This will determine whether specific abnormal heart rate, rhythm and conduction patterns emerge that characterize the condition, which will then allow the high risk obstetrician to better predict risk of fetal demise in the future. | ||||||||
Study Type | Observational | ||||||||
Study Design | Observational Model: Cohort Time Perspective: Prospective |
||||||||
Target Follow-Up Duration | Not Provided | ||||||||
Biospecimen | Not Provided | ||||||||
Sampling Method | Non-Probability Sample | ||||||||
Study Population | Current pregnancy complicated by one of the five diagnostic categories (fetal major congenital heart disease, prior unexplained Stillbirth at/after 20 weeks gestation, fetal hydrops, fetal gastroschesis, or monochorionic twin pregnancy. | ||||||||
Condition |
|
||||||||
Intervention | Diagnostic Test: Fetal Magnetocardiogram and Neonatal Electrocardiogram
Fetal Magnetocardiography (fMCG) is a new non-invasive diagnostic procedure that records tiny fetal cardiac signals similar to an Electrocardiogram or Holter monitor. The magnetometer has FDA clearance, and does not emit magnetic, electric or other energies. This is not an MRI. Examples of fetal MCG's can be found in the Links. The American Heart Association Scientific Statement on Fetal Diagnosis and Treatment (Circulation, 2014) has declared fMCG to be Class IIa for fetal heart rhythm abnormalities, meaning that benefit far exceeds risk. As part of this study, a neonatal electrocardiogram (nECG) will be obtained for comparison after the baby is born.
|
||||||||
Study Groups/Cohorts |
|
||||||||
Publications * |
|
||||||||
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||||||
Recruitment Information | |||||||||
Recruitment Status | Recruiting | ||||||||
Estimated Enrollment |
200 | ||||||||
Original Estimated Enrollment | Same as current | ||||||||
Estimated Study Completion Date | April 30, 2023 | ||||||||
Estimated Primary Completion Date | April 30, 2023 (Final data collection date for primary outcome measure) | ||||||||
Eligibility Criteria | Inclusion Criteria:
Exclusion Criteria:
The subject will have a single 2-3 hour fetal magnetocardiogram at approximately 20 and 27 weeks GA, and again, if medical condition allows, between 30 and 37 weeks GA, then her infant will have an ECG between 0 and 4 weeks of age. Subjects will be paid a nominal fee for their participation each time, as well as transportation reimbursement if >25 miles. For subjects traveling a long distance, the ECG may be performed locally or at home. |
||||||||
Sex/Gender |
|
||||||||
Ages | 18 Years and older (Adult, Older Adult) | ||||||||
Accepts Healthy Volunteers | No | ||||||||
Contacts |
|
||||||||
Listed Location Countries | United States | ||||||||
Removed Location Countries | |||||||||
Administrative Information | |||||||||
NCT Number | NCT03775954 | ||||||||
Other Study ID Numbers | PRO00031598 R01HL143485 ( U.S. NIH Grant/Contract ) |
||||||||
Has Data Monitoring Committee | No | ||||||||
U.S. FDA-regulated Product |
|
||||||||
IPD Sharing Statement |
|
||||||||
Current Responsible Party | Janette F. Strasburger, Medical College of Wisconsin | ||||||||
Original Responsible Party | Same as current | ||||||||
Current Study Sponsor | Medical College of Wisconsin | ||||||||
Original Study Sponsor | Same as current | ||||||||
Collaborators |
|
||||||||
Investigators |
|
||||||||
PRS Account | Medical College of Wisconsin | ||||||||
Verification Date | March 2023 |