CO2 vs. Air Insufflation for Endoscopic Ultrasound
![]() |
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
ClinicalTrials.gov Identifier: NCT02773563 |
Recruitment Status :
Completed
First Posted : May 16, 2016
Last Update Posted : April 10, 2017
|
Tracking Information | ||||
---|---|---|---|---|
First Submitted Date | May 12, 2016 | |||
First Posted Date | May 16, 2016 | |||
Last Update Posted Date | April 10, 2017 | |||
Study Start Date | April 2016 | |||
Actual Primary Completion Date | March 2017 (Final data collection date for primary outcome measure) | |||
Current Primary Outcome Measures |
Abdominal discomfort [ Time Frame: through study completion, an average of 1 year ] Self reported pain measurement after endoscopic ultrasound assessed with a Visual Analog Scale (VAS 0-10)
|
|||
Original Primary Outcome Measures | Same as current | |||
Change History | ||||
Current Secondary Outcome Measures |
|
|||
Original Secondary Outcome Measures | Same as current | |||
Current Other Pre-specified Outcome Measures | Not Provided | |||
Original Other Pre-specified Outcome Measures | Not Provided | |||
Descriptive Information | ||||
Brief Title | CO2 vs. Air Insufflation for Endoscopic Ultrasound | |||
Official Title | Role of CO2 Insufflation vs. Air Insufflation for Endoscopic Ultrasound: a Prospective Observational Study | |||
Brief Summary | The insufflation of air in the viscera is indispensable during endoscopy. However, the distension of the bowel that follows is often the cause of abdominal discomfort. Carbon dioxide (CO2) has been widely used for insufflation in endoscopy. CO2 insufflation is demonstrated in the literature to cause lower abdominal discomfort as it is quickly reabsorbed by the body. Endoscopic ultrasonography (EUS) is a method in which you associate the endoscopic view and the ultrasound vision obtained from the inside of the viscera. The diagnostic accuracy of EUS is undermined by the visual artifacts caused by the presence of air between the probe and the organ to be studied. Although the use of CO2 is already widely applied by many endoscopists, there are no studies to date concerning the use of CO2 during EUS from the point of view of the abdominal discomfort related to the procedure and/or the quality of the images obtained. The main purpose of the study is to assess whether the insufflation of CO2 results in a reduction of discomfort of the patients undergoing EUS. The study design is observational because no randomization or other interventions are planned; participants will be assigned to either air or CO2 insufflation according to the endoscopic room equipment (one room is equipped with CO2 insufflation while another endoscopic room is equipped just with air insufflation) and the results of the two groups will be compared. Among the secondary goals the investigators want to evaluate whether insufflation of CO2 is associated with a reduction in the dose required for patients sedation. Finally, the investigators want to clarify whether the use of CO2 is able to produce less visual artifacts than air and thus improve the quality of EUS images. |
|||
Detailed Description | The insufflation of air in the viscera during endoscopy is indispensable in order to allow the advancement of endoscopic probe, to visualize the mucosa and to avoid injury to the gastrointestinal wall. However, the distension of the bowel that follows is often the cause of abdominal discomfort since the air blown appears to be slightly absorbable and therefore it needs a long time to be expelled. Carbon dioxide (CO2) is a gas that has already been widely used for insufflation in endoscopy. CO2 insufflation is demonstrated in the literature to cause lower abdominal discomfort as it is quickly reabsorbed by the body. This gas is at the same time devoid of side effects. Studies in the literature focus mainly on the intensity of abdominal discomfort after the insufflation of CO2 vs. air while performing colonoscopy, endoscopic retrograde cholangiopancreatography (ERCP) and enteroscopy. Endoscopic ultrasonography (EUS) is a method in which you associate the endoscopic view and the ultrasound vision obtained from the inside of the viscera. The main indications to EUS are represented by the study of the biliary pancreatic diseases, the staging of the digestive tract tumors and the differential diagnosis of submucosal tumors. The diagnostic accuracy of EUS is undermined by the visual artifacts caused by the presence of air between the probe and the organ to be studied; during the procedure the endoscopist must ensure, by means of repeated suctions, that the least possible amount of air is present inside the viscera. Although the use of CO2 is already widely applied by many endoscopists, there are no studies to date concerning the use of CO2 during EUS from the point of view of the abdominal discomfort related to the procedure and/or the quality of the images obtained. At the moment, with regard to EUS, there are no recommendations regarding the use of a gas rather than the other; the choice is in fact at the discretion of the operator and also it depends on the availability in the individual endoscopic units of the instrumentation for CO2 insufflation. At Our Endoscopic Unit, CO2 or air insufflation is decided upon the availability of the equipment in the endoscopic room; in particular, in Suite 1, patients receive air insufflation and in Suite 2 they receive CO2 insufflation. The assignment into one or the other endoscopic room is purely casual according to scheduling the next free available slot. The main purpose of the study is to assess whether there is any difference between CO2 and air insufflation in inducing discomfort of the patients undergoing EUS. The study design is observational because no randomization or other intervention modifications are planned; participants will be assigned to either air or CO2 insufflation according to the endoscopic room equipment (one room is equipped with CO2 insufflation while another endoscopic room is equipped just with air insufflation) and the results of the two groups will be compared. Among the secondary goals the investigators want to evaluate whether insufflation of CO2 is associated with a reduction in the dose required for patients sedation. Finally, the investigators want to clarify whether the use of CO2 is able to produce less visual artifacts than air and thus improve the quality of EUS images. |
|||
Study Type | Observational | |||
Study Design | Observational Model: Case-Control Time Perspective: Prospective |
|||
Target Follow-Up Duration | Not Provided | |||
Biospecimen | Not Provided | |||
Sampling Method | Non-Probability Sample | |||
Study Population | Patients with indications for undergoing EUS (in general they are represented by patients with pancreaticobiliary or gastrointestinal diseases) | |||
Condition |
|
|||
Intervention |
|
|||
Study Groups/Cohorts |
|
|||
Publications * |
|
|||
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
||||
Recruitment Information | ||||
Recruitment Status | Completed | |||
Actual Enrollment |
200 | |||
Original Estimated Enrollment | Same as current | |||
Actual Study Completion Date | April 2017 | |||
Actual Primary Completion Date | March 2017 (Final data collection date for primary outcome measure) | |||
Eligibility Criteria | Inclusion Criteria: • Consecutive patients referred for EUS Exclusion Criteria:
|
|||
Sex/Gender |
|
|||
Ages | 18 Years to 85 Years (Adult, Older Adult) | |||
Accepts Healthy Volunteers | No | |||
Contacts | Contact information is only displayed when the study is recruiting subjects | |||
Listed Location Countries | Italy | |||
Removed Location Countries | ||||
Administrative Information | ||||
NCT Number | NCT02773563 | |||
Other Study ID Numbers | 2016/001 | |||
Has Data Monitoring Committee | No | |||
U.S. FDA-regulated Product | Not Provided | |||
IPD Sharing Statement |
|
|||
Responsible Party | Pietro Fusaroli, University of Bologna | |||
Study Sponsor | University of Bologna | |||
Collaborators | Not Provided | |||
Investigators |
|
|||
PRS Account | University of Bologna | |||
Verification Date | April 2017 |