Innovative SolutIons for DosimEtry in Hadrontherapy (INSIDE) (INSIDE)

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Know the risks and potential benefits of clinical studies and talk to your health care provider before participating. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT03662373
Recruitment Status : Not yet recruiting
First Posted : September 7, 2018
Last Update Posted : January 31, 2019
Sponsor:
Information provided by (Responsible Party):
CNAO National Center of Oncological Hadrontherapy

Brief Summary:

The study aim is to test the clinical feasibility and effectiveness of an online qualitative monitoring device named INSIDE system during hadrontherapy treatments.

This instrumentation is composed by detectors able to acquire secondary signals generated by the interaction of the primary beam with human tissues. From these measurements performed during irradiation, the INSIDE system estimates the particle beam range inside the patient's body and check the compliance of the ongoing treatment with the clinical prescription, with the aim to optimize the delivered dose.

The study aims to longitudinally monitor patients treated with hadrontherapy at the Italian National Centre of Oncological Hadrontherapy (CNAO) in Pavia in order to:

  • evaluate the stability of the INSIDE system response and the significance of the monitoring measurement;
  • study the clinical tolerances between ongoing and prescribed treatments within which the differences in particle range are not clinically relevant;
  • assess what impact an instrument such as the INSIDE system can have on the clinical routine;
  • evaluate the benefits of such a monitoring system with respect to treatment planning constraints.

Condition or disease Intervention/treatment
Particle Therapy Radiation: carbon ions radiation therapy Radiation: protons radiation therapy

Detailed Description:

A treatment monitoring instrumentation is highly demanded to maximize the benefits of hadrontherapy from the increased conformation of the released dose to the tumor volume with respect to the conventional radiotherapy.

Since almost all the energy of the charged particles is deposited in the end of their track (Bragg Peak region), the verification of the particle range by experimental measurements, performed during treatment delivery, can help to increase the therapy effectiveness while better sparing healthy tissues.

The INSIDE system is an innovative bi-modal instrumentation consisting of an in-beam Positron Emission Tomography (PET) scanner, to detect annihilation photons coming from positron isotope emitters, and a Dose Profiler to collect signals from charged particles emitted during treatment (e.g. protons in the case of carbon ion treatments).

The in-beam PET scanner is composed by two opposite panels of detectors placed above and below the patient bed, respectively. The Dose Profiler is positioned above the patient with an angle of 60°, forwardly with respect to the beam direction.

The INSIDE system is a passive instrumentation, i.e. no additional dose has to be released to the patient for particle range verification.

The INSIDE detectors are mounted on a mobile support and, immediately before the treatment delivery, they will be placed around the patient in the acquisition position, thanks to a dedicated hooking system designed to guarantee the maximum precision and accuracy in the particle range verification.

The INSIDE system mechanics is compatible with multi fields irradiation of patients affected by pathologies of Head-and-Neck and Brain districts.

In the clinical trial, patients affected by four selected pathologies will be included: meningioma and nasopharynx cancers treated with proton beams, Adenoid Cystic Carcinoma (ACC) and clival chordoma treated with carbon ion beams. These were chosen in order to study both projectile particles available at the CNAO centre (i.e., protons and carbon ions), and target specific pathologies which should most benefit from the range monitoring provided by the INSIDE system. Among them are cancers for which an early response is commonly observed and tumors which are located near cavities that can be filled with either water-like material (such as cancerous mass and inflamed tissues) or air.

The patients will undergo a longitudinal protocol of measurements in order to verify the agreement between the ongoing treatment and the prescription throughout the complete treatment period (lasting in average about 4-6 weeks for the selected pathologies).


Layout table for study information
Study Type : Observational
Estimated Enrollment : 40 participants
Observational Model: Cohort
Time Perspective: Prospective
Official Title: Sperimentazione Clinica Del Sistema INSIDE - Innovative SolutIons for DosimEtry in Hadrontherapy - Per il Monitoraggio Del Trattamento in Adroterapia
Estimated Study Start Date : June 15, 2019
Estimated Primary Completion Date : December 15, 2019
Estimated Study Completion Date : June 30, 2020

Group/Cohort Intervention/treatment
carbon ions radiation therapy
the group of patients treated with carbon ion radiation therapy, affected by one of the four pathologies foreseen in inclusion criteria
Radiation: carbon ions radiation therapy
Carbon ion radiation therapy to treat adenoid cystic carcinoma, skull base (clivus) chordoma.
Other Name: particle therapy

protons radiation therapy
the group of patients treated with proton radiation therapy, affected by one of the four pathologies foreseen in inclusion criteria
Radiation: protons radiation therapy
Proton radiation therapy used to treat meningioma and squamocellular rhinopharynx carcinoma
Other Name: particle therapy




Primary Outcome Measures :
  1. particles ranges [ Time Frame: average of 5 weeks (as a treatment duration) ]
    evaluate the quality of treatments in term of data collection and of particles range evaluated with PET scanner and Monte Carlo simulations

  2. particles ranges for each pathology considered [ Time Frame: 4 months ]
    statistical analysis to assess the evaluations of treatment



Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   18 Years and older   (Adult, Older Adult)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Sampling Method:   Non-Probability Sample
Study Population
Study population is represented by all patients undergoing to treatment at CNAO, selected on the pathology and on the particle used for their radiation therapy. 40 patients affected by one of the four pathologies foreseen and which can offer morphological variations during treatment cycle.
Criteria

Inclusion Criteria:

  • patients treated at CNAO with protons or carbon ions with horizontal beam line.
  • meningioma, ACC, skull base (clivus) chordoma, squamous cellular rhinopharynx carcinoma
  • full compatibility of the INSIDE monitoring system with all beam delivery devices in the established irradiating position
  • all emergency procedures are possible notwithstanding INSIDE system positioned.
  • signed written informed consent by patient.

Exclusion Criteria

  • missing informed consent
  • not affected by one of the selected pathologies
  • failure of pre-treatment compatibility technical assessment
  • failure of pre-treatment emergency procedures check
  • medical or individual reasons (i.e. short time test needed)

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT03662373


Contacts
Layout table for location contacts
Contact: Viviana Vitolo, MD 00390382078501 vitolo@cnao.it
Contact: Francesca Valvo, MD 00390382078501 direzionemedica@cnao.it

Locations
Layout table for location information
Italy
CNAO Not yet recruiting
Pavia, Italy, 27100
Contact: Cristina Bono, MSc    +39(0)382078613    cristina.bono@cnao.it   
Sponsors and Collaborators
CNAO National Center of Oncological Hadrontherapy
Investigators
Layout table for investigator information
Principal Investigator: Viviana Vitolo, MD CNAO National Center of Oncological Hadrontherapy

Layout table for additonal information
Responsible Party: CNAO National Center of Oncological Hadrontherapy
ClinicalTrials.gov Identifier: NCT03662373     History of Changes
Other Study ID Numbers: CNAO-OSSINSIDE-02-18
First Posted: September 7, 2018    Key Record Dates
Last Update Posted: January 31, 2019
Last Verified: September 2018

Layout table for additional information
Studies a U.S. FDA-regulated Drug Product: No
Studies a U.S. FDA-regulated Device Product: No
Keywords provided by CNAO National Center of Oncological Hadrontherapy:
on line monitoring
PET in beam
Hadrontherapy