Simplified Pulse Wave Velocity Measurement, Validation Study of the pOpmètre in Children (EPIPOP)

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT02991703
Recruitment Status : Unknown
Verified December 2016 by Nantes University Hospital.
Recruitment status was:  Not yet recruiting
First Posted : December 13, 2016
Last Update Posted : December 13, 2016
Sponsor:
Information provided by (Responsible Party):
Nantes University Hospital

Brief Summary:
Arterial stiffness is an important marker of cardiovascular risk. It is measured by pulse wave velocity. The reference device to measure pulse wave velocity is the Sphygmocor which uses applanation tonometry. It is used in adults and children. An easier method called pOpmètre using saturation sensors is validated in adults but not in children. The objective of this study is to compare the pulse wave velocity values measured with the pOpmètre® with those of the SphygmoCor® to validate the pOpmètre in children between 4 and 8 years old.

Condition or disease Intervention/treatment Phase
Cardiovascular Diseases Arteriosclerosis Atherosclerosis Device: pOpmètre® Device: Sphygmocor Not Applicable

Detailed Description:
Prematurity is associated with an increased risk of developing cardio-vascular diseases in adulthood : a low birth weight linked to prematurity is correlated to a higher coronary disease mortality rate, a higher blood pressure level in adulthood, to abnormal glucose metabolism regulation, and to signs of nephron reduction. An independent marker of cardiovascular risk is arterial stiffness: it is associated with a higher risk of major cardiovascular events including stroke, acute coronary syndrome and complications of end-stage renal disease. It is measured by pulse wave velocity which is the gold standard in adulthood. Pulse wave velocity is also correlated to cardiovascular risk in childhood. National cohort EPIPAGE II is made of 4290 premature babies born in 2011. A study is scheduled at 5 years old and a half including a medical examination and a neuropsychological evaluation. An ancillary study lengthening medical consultation for 15 minutes is scheduled with 750 to 1000 of these children for a more precise vascular evaluation including pulse wave velocity. Different methods can be used to measure pulse wave velocity in children: these include applanation tonometry devices such as the SphygmoCor ® system. Its reference values are well known in adulthood and were determined more recently in childhood. It is the reference device but it is expensive, can be used only in expert health centres and time of measurement is long. In children, an easier-to-use and faster device would be more advantageous. The pOpmètre® uses 2 distal oxygen saturation sensors on finger and toe to deduce pulse wave velocity. This device has already been validated in adults. The aim of this study is to validate the pOpmètre in children between 4 and 8 years old. In that purpose, patients are installed in the supine position, at rest. The child's mensurations are measured. The two pOpmètre sensors are put on finger and toe. Blood pressure is measured by an armband on the right limb. Then another armband is put around the thigh and a tonometer is applied on the right carotid which allows pulse wave velocity measuring by the Sphygmocor. Pulse wave velocity is measured with the pOpmètre using the time delay between finger pulse signal and toe pulse signal. The values got with the two devices are compared using a Bland and Altman graph. The pOpmètre is considered to be validated if the 95% confidence interval of the bias is included between -0.5 m/sec and 0.5 m/sec that is about 10% of the normal value at that age (5.0 m/s +/-0.13).

Layout table for study information
Study Type : Interventional  (Clinical Trial)
Estimated Enrollment : 60 participants
Allocation: Non-Randomized
Intervention Model: Parallel Assignment
Masking: None (Open Label)
Primary Purpose: Diagnostic
Study Start Date : December 2016
Estimated Primary Completion Date : November 2017
Estimated Study Completion Date : November 2017

Arm Intervention/treatment
Active Comparator: SphygmoCor® Device: Sphygmocor
the Sphygmocor uses applanation tonometry

Experimental: pOpmètre® Device: pOpmètre®
the pOpmètre® uses saturation sensors,




Primary Outcome Measures :
  1. Difference between the two simultaneous measurements of velocity of the pulse wave by the pOpmeter® and the Sphygmocor®. [ Time Frame: Day One ]


Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   4 Years to 8 Years   (Child)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • children between 4 and 8 years old hospitalized in the Mother and Children Hospital in Nantes during the study period.

Exclusion Criteria:

  • Vasoconstrictor treatment,
  • compressive bandage on the measured area,
  • peripheral venous access on the measured side,
  • vascular surgery or pathology on the measured area,
  • significant pain or agitation,
  • parental or legal representative disapproval,
  • child disapproval.

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT02991703


Contacts
Layout table for location contacts
Contact: Jean-Christophe ROZE, Pr jeanchristophe.roze@chu-nantes.fr
Contact: Emma Allain-Launay, Dr 02 40 08 36 60 emma.allainlaunay@chu-nantes.fr

Sponsors and Collaborators
Nantes University Hospital
Additional Information:
Publications:

Publications automatically indexed to this study by ClinicalTrials.gov Identifier (NCT Number):
Layout table for additonal information
Responsible Party: Nantes University Hospital
ClinicalTrials.gov Identifier: NCT02991703    
Other Study ID Numbers: RC16_0161
First Posted: December 13, 2016    Key Record Dates
Last Update Posted: December 13, 2016
Last Verified: December 2016
Keywords provided by Nantes University Hospital:
Arterial stiffness
pulse wave velocity
Sphygmocor
applanation tonometry
pOpmètre
children
EPIPAGE cohort
Additional relevant MeSH terms:
Layout table for MeSH terms
Cardiovascular Diseases
Atherosclerosis
Arteriosclerosis
Arterial Occlusive Diseases
Vascular Diseases