Methods for the Measurement of Respiratory Rate

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT02672007
Recruitment Status : Completed
First Posted : February 3, 2016
Last Update Posted : March 24, 2016
Sponsor:
Information provided by (Responsible Party):
Niels Egholm Pedersen, Herlev Hospital

Brief Summary:

This study aims to investigate these research questions:

  1. Is there a difference in the results obtained, when respiratory rate is measured automatically by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with a research assistant using a criterion standard approach?
  2. Is there a difference in the results obtained, when respiratory rate is measured automatically by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with hospital staff's current clinical practice?

Condition or disease Intervention/treatment Phase
Respiratory Rate Measurement Methods. Device: SensiumVitals Not Applicable

Detailed Description:

Respiratory rate is among the first vital signs to change when a deterioration in patient conditions occurs, and that it is highly useful in identifying high-risk patients, patients in pain, risk of death in patients treated for myocardial infarctions and medical patients at risk of cardiac arrest.

Respiratory rate is one of the seven physiological parameters included in the Early Warning Score (EWS), an aggregated track- and trigger-system for risk-stratification of patients in hospital wards at risk of imminent clinical deterioration. EWS includes an escalation protocol, defining when it is necessary for the ward staff to call for assistance and when vital parameters should be measured again.

Manual measurement of respiratory rates is the standard in hospital wards in the Capital Region of Denmark. During the measurement of respiratory rate, patients ideally have to lie still and refrain from talking. This poses a difficulty in daily, clinical practice. Several studies in hospital wards both using and not using an EWS-system report that respiratory rate is often omitted when vital signs are measured.

Even if the respiratory rate is measured regularly, poor inter-observer agreement and reproducibility of measured respiratory rates have been found. Respiratory rates recorded by nurses have been reported to be generally higher than those measured by observers using a standardised approach.

The EWS currently in use is validated using measurements obtained by normal nursing practise. If there is an element of human influence on the measurement of respiratory rate, automation could affect the prognostic properties of EWS in an unpredictable way, even if the automatically measured respiratory rates more reliably reflect the patients' physiology than current clinical practise.

If a systematic difference between the recordings by staff and the electronic devices currently on the market exists, this could have an implication on the EWS scores and subsequently, escalation protocols for patients with elevated EWS could be affected. If this is the case, EWS might even have to be re-validated using machine-measured respiratory rates.

Thus, even as there could be a number of advantages of automating the measurements of respiratory rates in hospital wards, due considerations are required before ward staff's manual measurement of respiratory rate can be replaced by measurements obtained from electronic devices. The purpose of this study is to evaluate if there is a systematic difference in the respiratory rate measurements performed by an electronic device (SensiumVitals® system, Sensium Healthcare) compared with the measurements performed by a research assistant using a criterion standard approach and the ward staff's usual measurements.

Layout table for study information
Study Type : Interventional  (Clinical Trial)
Actual Enrollment : 50 participants
Allocation: N/A
Intervention Model: Single Group Assignment
Primary Purpose: Diagnostic
Official Title: Methods for the Measurement of Respiratory Rate
Study Start Date : January 2016
Actual Primary Completion Date : February 2016
Actual Study Completion Date : February 2016

Arm Intervention/treatment
Included patients
All included patients will have respiratory rates measured by a research assistant using a criterion standard approach, by the SensiumVitals device and by the ward staff.
Device: SensiumVitals
The patients will have their respiratory rates, heart rates and temperature (axilla) measured continuously by the SensiumVitals patch.




Primary Outcome Measures :
  1. Difference in respiratory rate recorded by the research assistant using a criterion standard approach and the SensiumVitals device [ Time Frame: 24 Hours ]
    After enrolment at the general, medical short-time ward a research assistant will measure the patient's respiratory rate using a criterion standard approach. The time of this measurement will be registered, and the corresponding measurement made by the SensiumVitals device will be extracted and used for the comparison. Reported with Bland-Altman plots.


Secondary Outcome Measures :
  1. Difference in respiratory rate recorded by the ward staff using standard clinical practice and the SensiumVitals device [ Time Frame: 24 Hours ]
    The ward staff's first measurement of respiratory rate after the patient is enrolled in the study at the general, medical short-time ward as registered in the electronic patient journal. The time of this measurement will be registered, and the corresponding measurement made by the SensiumVitals device will be extracted and used for the comparison. Reported with Bland-Altman plots.


Other Outcome Measures:
  1. Early Warning Score recorded by the research assistant [ Time Frame: 24 Hours ]
    Early Warning Score (point score) will be recorded using standard practice by the research assistant. Parameters included in the Early Warning Score: Peripheal arterial oxygen satuation (%), pulse (beats per minute), use of supplementary oxygen (liters per minute), systolic and diastolic blood pressure (mmHg), level of consciousness (AVPU-scale), temperature (degrees celcius) and pulse regularity (yes/no).

  2. Early Warning Score recorded by the ward staff [ Time Frame: 24 Hours ]
    Early Warning Score (point score) recorded using standard practice by the ward staff. Early Warning Score consists of: Peripheal arterial oxygen satuation (%), pulse (beats per minute), use of supplementary oxygen (liters per minute), systolic and diastolic blood pressure (mmHg), level of consciousness (AVPU-scale) and temperature (degrees celcius).



Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   18 Years and older   (Adult, Older Adult)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • Age 18 years or older.
  • Able and willing to give informed consent to participation in the study and necessary data collection.
  • Admitted to the general medical short-time ward and planned stay there at the time of inclusion greater than two hours.

Exclusion Criteria:

  • Wounds, burns or other conditions that prevent proper attachment of the measurement device, or where wearing the device might cause or increase discomfort from wearing the device.
  • Allergies to medical graded tape or ECG electrodes.
  • Patients with cardiac pacemaker or implanted defibrillator.
  • Any condition or situation preventing proper information, consent and enrolment.
  • Respiratory rate measurements by another device using impedance pneumography.

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT02672007


Locations
Layout table for location information
Denmark
Copenhagen Academy for Medical Education and Simulation and Medical-Short Time Ward, Herlev Hospital
Herlev, Denmark, 2730
Sponsors and Collaborators
Herlev Hospital
Investigators
Layout table for investigator information
Principal Investigator: Niels E Pedersen, MD Copenhagen Academy for Medical Education and Simulation, Herlev Hospital, Center for HR, Capital Region of Denmark
Layout table for additonal information
Responsible Party: Niels Egholm Pedersen, MD, PhD student, Herlev Hospital
ClinicalTrials.gov Identifier: NCT02672007    
Other Study ID Numbers: CAMES-16-001
First Posted: February 3, 2016    Key Record Dates
Last Update Posted: March 24, 2016
Last Verified: March 2016
Keywords provided by Niels Egholm Pedersen, Herlev Hospital:
Respiratory rate measurement methods.