Brief Summary:
Tissue oxygen saturation is non-invasively measured using near-infrared spectroscopy, by two device, INVOS®(somanetics Corporation, USA ) and InSpectra™ (Hutchinson Technology, USA). Each probes are attached to both thenar muscles and vascular occlusion test (VOT) is performed. The investigators will compare the Invos® data to InSpectra™ to investigate whether tissue oxygen saturation values by INVOS® can substitute for InSpectra™.

Condition or disease Intervention/treatment Phase
Healthy Device: vascular occlusion test Not Applicable

Detailed Description:

Tissue oxygen saturation is non-invasively measured using near-infrared spectroscopy, by two device, INVOS®(somanetics Corporation, USA ) and InSpectra™ (Hutchinson Technology, USA). InSpectra™ was introduced later than INVOS®.

With InSpectra™, clinicians have used a vascular occlusion test (VOT) to evaluate dynamic changes in tissue oxygen saturation during ischemia and reperfusion, and thus, microcirculatory function. There have been little data about VOT using INVOS®, although it is more popular device.

We hypothesized that there would be a difference between the values from INVOS® and InSpectra™. The aim of this study is to evaluate changes in tissue oxygen saturation in the thenar muscle during VOT using INVOS® and comapre it to InSpectra™ in a normal population.


Layout table for study information
Study Type : Interventional  (Clinical Trial)
Actual Enrollment : 20 participants
Intervention Model: Single Group Assignment
Masking: Double (Investigator, Outcomes Assessor)
Primary Purpose: Diagnostic
Official Title: Comparison of Two Devices Using Near-infra Red Spectroscopy for the Measurement of Tissue Oxygenation During a Vascular Occlusion Test (INVOS® Versus Inspectra™)
Study Start Date : January 2013
Actual Primary Completion Date : April 2013
Actual Study Completion Date : April 2013

Arm Intervention/treatment
Experimental: vascular occlusion test

The pediatric SomaSensor™ probe of INVOS® and the 15-mm sensor of InSpectra™ are placed on each thenar muscle in the same subject. The side on which the probe will be placed is randomly determined. INVOS® updates data every 5 s and data (SrO2) will be manually recorded. The data of InSpectra™ (StO2) are automatically collected and sampled every 2 s.

Vascular occlusion test (VOT) is done as follows:Adult-size blood pressure cuffs are placed around each upper arm. The both cuffs are simultaneously inflated to 30 mmHg above the initial systolic blood pressure and kept inflated until the SrO2 or StO2 decreased to 40%. When the value reaches 40% or just below it, the cuff on the same side is deflated rapidly. The data will be collected until the SrO2 and StO2 values returned to the baseline.

Device: vascular occlusion test
Using Invos® probe attacted to one thenar muscle, tissue oxgyenation is measured by VOT.

Device: vascular occlusion test
Using Inspectra™ probe attacted to another thenar muscle, tissue oxgyenation is measured by VOT.




Primary Outcome Measures :
  1. Change of Tissue Oxygenation Value During Ischemia and Reperfusion Period Until Basline Value Was Achieved [ Time Frame: Until basline tissue oxygenation value was achieved ]
    During vascular occlusion test, the changes of StO2 and SrO2 values can divided into 3 epoch; Desaturation, Reoxygenation and Reactive hyperemia. After data collection, the rate of desaturation and reoxygenation were calculated.

  2. Sum of Tissue Oxygenation Value Which Above Basline Value After Reperfusion Period Until Basline Value Was Achieved [ Time Frame: Until basline tissue oxygenation value was achieved ]
    During vascular occlusion test, the changes of StO2 and SrO2 values can divided into 3 epoch; Desaturation, Reoxygenation and Reactive hyperemia. After data collection, the rate of desaturation and reoxygenation were calculated.


Secondary Outcome Measures :
  1. Baseline, Miminum and Maximum Tissue Oxygenation Value Measured by INVOS® (SrO2) Until Basline Value Was Achieved [ Time Frame: Until basline tissue oxygenation value was achieved ]
    Before VOT. basline StO2 and SrO2 were recorded and compared each other. During VOT, minimum/maximum StO2 and SrO2 were also recorded and compared each other.



Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   26 Years to 41 Years   (Adult)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   Yes
Criteria

Inclusion Criteria:

  • healthy subject

Exclusion Criteria:

  • age under 18 years old
  • with arteriovenous fistula
  • with peripheral vessel disease
  • taking vasoactive drug
  • with a skin ailment
  • with HTN, DM
  • with diagnosed heart disease

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT01848977


Sponsors and Collaborators
Seoul National University Hospital
Investigators
Layout table for investigator information
Study Director: Jin-Tae Kim, Ph.D. Seoul National University Hospital

Layout table for additonal information
Responsible Party: Jin-Tae Kim, Ph.D., Seoul National University Hospital
ClinicalTrials.gov Identifier: NCT01848977     History of Changes
Other Study ID Numbers: H-1302-016-462
First Posted: May 8, 2013    Key Record Dates
Results First Posted: January 26, 2015
Last Update Posted: January 26, 2015
Last Verified: January 2015

Keywords provided by Jin-Tae Kim, Seoul National University Hospital:
Measures
near-Infrared spectroscopy
ischemia
reperfusion