A Comparison of the Blom Low Profile Voice Inner Cannula and the Passy-Muir One-Way Tracheotomy Tube Speaking Valve on Voice Production, Speech Intelligibility, and Biomechanical Swallowing Behavior

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT01784224
Recruitment Status : Completed
First Posted : February 5, 2013
Last Update Posted : June 13, 2014
Sponsor:
Information provided by (Responsible Party):
Yale University

Brief Summary:

The main purpose of this study is to investigate voice production, speech intelligibility and routine physiologic parameters associated with the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves.

Additionally, the purpose of this study is to investigate the effects (if any) associated with the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves on swallowing behavior and biomechanical movement of the hyolaryngeal complex during routine diagnostic modified barium swallowing evaluations.


Condition or disease Intervention/treatment Phase
Mechanical Complication of Tracheostomy Procedure: Blom Low Profile Voice Cannula/Passty-Muir Speaking Valves Not Applicable

Detailed Description:

The goal of a one-way tracheotomy tube speaking valve is to allow cognitively intact individuals who require a tracheotomy tube communicate with their own voice. All non-verbal communication strategies have shortcomings. Lip reading is unreliable, communication boards are simplistic, writing very laborious, and computerized augmentative communication systems too costly. This inability to communicate effectively prevents optimal patient participation in their plan-of-care. Verbal communication, therefore, plays an integral role in psychological functioning, social interactions, and overall medical care.

The primary criteria for determining success or failure of any one-way tracheotomy tube speaking valve is how well it allows for adequate voice intensity greater than ambient room noise to achieve both audible voice production and intelligible speech. The first purpose of this study is to investigate voice production and speech intelligibility abilities associated with the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves. It is hypothesized that there will be no significant differences between the two speaking valves regarding physiologic parameters, voice production, or speech intelligibility capabilities.

There are conflicting reports in the literature regarding the relationship between a tracheotomy tube and swallowing success. Some authors report an improvement in swallowing success when the tracheotomy tube is occluded while others report no change in aspiration status based on occlusion status of the tracheotomy tube. Recently, it has been reported that there was no causal relationship between the tracheotomy tube and aspiration status. There is a paucity of research, to date, reporting on movement of the hyolaryngeal complex based upon occlusion status of a tracheotomy tube or presence of a tracheotomy tube. The second purpose of this study is to investigate how the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves impact on swallowing behavior and movement of the hyolaryngeal complex during routine diagnostic modified barium swallow evaluations.


Layout table for study information
Study Type : Interventional  (Clinical Trial)
Actual Enrollment : 30 participants
Intervention Model: Single Group Assignment
Masking: None (Open Label)
Primary Purpose: Treatment
Official Title: A Comparison of the Blom Low Profile Voice Inner Cannula and the Passy-Muir One-Way Tracheotomy Tube Speaking Valve on Voice Production, Speech Intelligibility, and Biomechanical Swallowing Behavior
Study Start Date : January 2013
Actual Primary Completion Date : October 2013
Actual Study Completion Date : October 2013

Arm Intervention/treatment
Experimental: Speaking Valves

All participants will either have a Blom tracheotomy tube in place or have their current tracheotomy tube changed to a Blom tracheotomy tube to allow for use of both the Blom low profile voice inner cannula and the Passy-Muir one-way speaking valves.

The Blom low profile voice inner cannula and Passy-Muir speaking valves will be provided to participants in a random order. All valves will be placed by the PI. Duration of data collection trials will range from 10 to 30 minutes.

Procedure: Blom Low Profile Voice Cannula/Passty-Muir Speaking Valves



Primary Outcome Measures :
  1. Maximum Duration of Voicing (seconds) [ Time Frame: 30 minutes ]
    Maximum duration of voicing (seconds) will be obtained, after instructing the patient to say the vowel /a/ as long as possible timed with a stopwatch.

  2. Maximum Voice Intensity (dBA scale) [ Time Frame: 30 minutes ]
    Maximum voice intensity (on the dBA scale) will be obtained, after instructing the patient to say the vowel /a/ as loud as possible, using a digital sound level meter placed 15 cm from the patient's lips.



Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   18 Years and older   (Adult, Older Adult)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • Over 18 years of age, English speaking, and ability to tolerate a tracheotomy tube with a fully deflated tracheotomy tube cuff.

Exclusion Criteria:

  • Inability to tolerate full tracheotomy tube cuff deflation or copious secretions preventing placement of a one-way tracheotomy tube speaking valve.

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT01784224


Locations
Layout table for location information
United States, Connecticut
Yale University School of Medicine
New Haven, Connecticut, United States
Sponsors and Collaborators
Yale University

Layout table for additonal information
Responsible Party: Yale University
ClinicalTrials.gov Identifier: NCT01784224     History of Changes
Other Study ID Numbers: 1206010346
First Posted: February 5, 2013    Key Record Dates
Last Update Posted: June 13, 2014
Last Verified: June 2014