| Sponsor: | Hologic, Inc. |
|---|---|
| Information provided by: | Hologic, Inc. |
| ClinicalTrials.gov Identifier: | NCT00979342 |
Purpose
The purpose of this study is to develop a recommended local anesthetic protocol and post-treatment pain management regimen, in order to assure patient comfort during office-based treatment with the MyoSure Hysteroscopic Tissue Removal Device. Subject self-reported pain scores (as rated on an 11 point scale) will be compared at multiple time intervals between all treatment groups.
| Condition | Intervention |
|---|---|
|
Uterine Fibroids Polyps |
Device: Hysteroscopic Morcellator |
| Study Type: | Interventional |
| Study Design: | Allocation: Randomized Endpoint Classification: Safety/Efficacy Study Intervention Model: Parallel Assignment Masking: Open Label Primary Purpose: Treatment |
| Official Title: | Interlace Medical Comparative Sedation Study |
| Enrollment: | 40 |
| Study Start Date: | November 2009 |
| Study Completion Date: | July 2010 |
| Primary Completion Date: | July 2010 (Final data collection date for primary outcome measure) |
| Arms | Assigned Interventions |
|---|---|
|
Experimental: Cervical Block, 6 injection sites
Subject will receive a cervical block of 1% lidocaine and 0.25% bupivacaine, with injections in the following locations: 2cc at 12:00, 10cc at 3:00, 10 cc at 9:00, 5 cc at 4:00, 5 cc at 8:00, and 5 cc at 6:00.
|
Device: Hysteroscopic Morcellator
The MyoSure Tissue Removal Device consists of a hand-held tissue removal device comprising a mechanical drive assembly connected to a drive cable and associated control box on one end, and a 3 mm shaft on the other end of the device. The shaft is approximately 12 cm long and equipped with an open channel that houses an oscillating blade.When the side channel is exposed to target tissue and the motor is activated, the oscillating blade will cut the tissue within the channel. Once cut, the tissue travels down the center of the 3mm shaft via suction coupled to the proximal end of the tissue removal device, and is trapped in a vacutainer bottle.
Other Names:
|
|
Experimental: Cervical Block, 2 injection sites
Subject will receive a cervical block of 1% lidocaine and 0.25% bupivacaine, with injections in the following locations: 10 cc at 4:00, and 10 cc at 8:00.
|
Device: Hysteroscopic Morcellator
The MyoSure Tissue Removal Device consists of a hand-held tissue removal device comprising a mechanical drive assembly connected to a drive cable and associated control box on one end, and a 3 mm shaft on the other end of the device. The shaft is approximately 12 cm long and equipped with an open channel that houses an oscillating blade.When the side channel is exposed to target tissue and the motor is activated, the oscillating blade will cut the tissue within the channel. Once cut, the tissue travels down the center of the 3mm shaft via suction coupled to the proximal end of the tissue removal device, and is trapped in a vacutainer bottle.
Other Names:
|
|
Experimental: Ibuprofen q. 8 hours
Subjects will receive a post procedure pain management regimen of ibuprofen 800 mg every 8 hours, for the first 24 hours and then PRN.
|
Device: Hysteroscopic Morcellator
The MyoSure Tissue Removal Device consists of a hand-held tissue removal device comprising a mechanical drive assembly connected to a drive cable and associated control box on one end, and a 3 mm shaft on the other end of the device. The shaft is approximately 12 cm long and equipped with an open channel that houses an oscillating blade.When the side channel is exposed to target tissue and the motor is activated, the oscillating blade will cut the tissue within the channel. Once cut, the tissue travels down the center of the 3mm shaft via suction coupled to the proximal end of the tissue removal device, and is trapped in a vacutainer bottle.
Other Names:
|
|
Experimental: Ibuprofen PRN
Subjects will receive a post procedure pain management regimen of ibuprofen 800 mg PRN.
|
Device: Hysteroscopic Morcellator
The MyoSure Tissue Removal Device consists of a hand-held tissue removal device comprising a mechanical drive assembly connected to a drive cable and associated control box on one end, and a 3 mm shaft on the other end of the device. The shaft is approximately 12 cm long and equipped with an open channel that houses an oscillating blade.When the side channel is exposed to target tissue and the motor is activated, the oscillating blade will cut the tissue within the channel. Once cut, the tissue travels down the center of the 3mm shaft via suction coupled to the proximal end of the tissue removal device, and is trapped in a vacutainer bottle.
Other Names:
|
Forty subjects will be enrolled in a randomized, controlled study conducted at four physician offices or day surgery settings. Subjects will be randomized 1:1 to a local anesthetic group (Group #1 or Group #2). Subjects will undergo a hysteroscopic tissue removal procedure to remove intrauterine polyps, type 0 fibroids, or type I fibroids. Subsequent to the procedure, subjects will be randomized 1:1 within the local anesthetic group to a post procedure pain management group (Group A or Group B). Subject self-reported pain scores (as rated on an 11 point scale)will be compared at three time points: Immediately post procedure, prior to discharge from the treatment facility, and at 48 hours post procedure.
Eligibility| Ages Eligible for Study: | 18 Years to 65 Years |
| Genders Eligible for Study: | Female |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:
Subject exhibits intrauterine polyps and/or submucous myomas which meet one of the following criteria. In cases of subjects with multiple intrauterine pathology, classification is based as follows:
Exclusion Criteria:
Contacts and Locations| United States, Arizona | |
| Phoenix Gynecology Consultants | |
| Phoenix, Arizona, United States, 85013 | |
| United States, Florida | |
| Florida Woman Care | |
| Boca Raton, Florida, United States, 33431 | |
| United States, Michigan | |
| Wayne State University | |
| Detroit, Michigan, United States, 48201 | |
| United States, Minnesota | |
| Minnesota Gynecology and Surgery | |
| Edina, Minnesota, United States, 55435 | |
| United States, North Carolina | |
| Carolina Women's Research and Wellness Center | |
| Durham, North Carolina, United States, 27713 | |
| Principal Investigator: | Andrea Lukes, MD | Carolina Women's Research and Wellness Center |
More Information
| Responsible Party: | John Vozella, V.P Clinical & Regulatory Affairs, Interlace Medical, Inc, |
| ClinicalTrials.gov Identifier: | NCT00979342 History of Changes |
| Other Study ID Numbers: | TMP 200902 |
| Study First Received: | September 17, 2009 |
| Last Updated: | July 22, 2010 |
| Health Authority: | United States: Institutional Review Board |
|
morcellator hysteroscope myomectomy polypectomy uterine fibroids |
uterine polyps local anesthetic cervical block pain management |
|
Leiomyoma Myofibroma Polyps Neoplasms, Muscle Tissue Neoplasms, Connective and Soft Tissue Neoplasms by Histologic Type Neoplasms Neoplasms, Connective Tissue Connective Tissue Diseases Pathological Conditions, Anatomical Ibuprofen Anti-Inflammatory Agents, Non-Steroidal Analgesics, Non-Narcotic |
Analgesics Sensory System Agents Peripheral Nervous System Agents Physiological Effects of Drugs Pharmacologic Actions Anti-Inflammatory Agents Therapeutic Uses Antirheumatic Agents Cyclooxygenase Inhibitors Enzyme Inhibitors Molecular Mechanisms of Pharmacological Action Central Nervous System Agents |