Purpose
The primary objective of the study is to demonstrate that the performance of the modified Plasmat® Futura H.E.L.P. Apheresis System is non-inferior to the current FDA approved Plasmat® Secura H.E.L.P Apheresis System for use under the approved indication of the acute reduction of LDL-cholesterol from the plasma in populations for whom diet has been ineffective and maximum drug therapy has either been ineffective or not tolerated.
| Condition | Intervention |
|---|---|
|
Hypercholesterolemia |
Device: Secura Device: Futura Device: Futura Device: Secura |
| Study Type: | Interventional |
| Study Design: | Allocation: Randomized Endpoint Classification: Safety/Efficacy Study Intervention Model: Crossover Assignment Masking: Open Label |
| Official Title: | Randomized Multicenter Crossover Study to Compare the Plasmat® Futura Heparin Induced Extracorporeal Lower Density Lipo-Protein (LDL) Precipitation (H.E.L.P.) Apheresis System to the Approved Secura System in the Reduction of LDL-c in Patients With Hypercholesterolemia |
Apheresis Machine Physical parameters; Parameter Description (Abbreviation) Plasmat® Secura Plasma Flow (Plasma Pump) Plasma Pressure 1 (PLP 1) Plasma Pressure 2 (PLP 2) Filtration Pressure 1 (FP 1) Transmembrane Pressure (TMP) Plasmat® Futura Plasma Flow (Plasma Pump) Pressure at Precipitate Filter (PPF) Pressure at Dialysis Filter (PDF) Pressure Drop Across Precipitate Adsorber (PDPA)*
| Enrollment: | 18 |
| Study Start Date: | August 2007 |
| Study Completion Date: | December 2008 |
| Primary Completion Date: | October 2008 (Final data collection date for primary outcome measure) |
| Arms | Assigned Interventions |
|---|---|
|
A
The Group Randomized first to the approved Plasmat® Secura apheresis system and then to the Plasmat® Futura apheresis system.
|
Device: Secura Device: Futura
Randomized to 6 bi-monthly H.E.L.P. therapy treatments with the Plasmat® Secura apheresis system and then cross over to receive 6 bi-monthly treatments with the Plasmat® Futura apheresis system.
|
|
B
The Group Randomized first to the approved Plasmat® Futura apheresis system and then to the Plasmat® Secura apheresis system.
|
Device: Futura Device: Secura
Randomized to 6 bi-monthly H.E L.P. therapy treatments with the Plasmat® Futura apheresis system and then cross over to receive 6 bi-monthly treatments with the Plasmat® Secura apheresis system.
|
The primary study endpoint is the change in percent measurements of the pre-to-post apheresis LDL measurements between the approved H.E.L.P. system and the modified H.E.L.P. system. The secondary study endpoints are clinical lab profiles and device parameters analyzed at specific time points throughout the study.
Eligibility| Ages Eligible for Study: | 25 Years to 70 Years |
| Genders Eligible for Study: | Both |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:
Sterile, post-menopausal, or using acceptable birth control for the duration of the study. Acceptable birth control is defined as having a vasectomized, postmenopausal, or sterile partner; the ongoing use of approved hormonal contraceptives, barrier method, or an intrauterine device; or abstinence.
Exclusion Criteria:
Contacts and Locations| United States, Connecticut | |
| Hartford Hospital | |
| Hartford, Connecticut, United States, 06102 | |
| United States, Kansas | |
| University of Kansas Medical Center | |
| Kansas City, Kansas, United States, 66160 | |
| Principal Investigator: | Patrick Moriarty, M.D. | University of Kansas |
| Principal Investigator: | Paul Thompson, M.D. | Hartford Hospital |
More Information
| Responsible Party: | Susan Olinger, B. Braun Medical Inc. |
| ClinicalTrials.gov Identifier: | NCT00526058 History of Changes |
| Other Study ID Numbers: | LDLc-A-US2-0406 |
| Study First Received: | September 5, 2007 |
| Results First Received: | May 25, 2010 |
| Last Updated: | July 30, 2010 |
| Health Authority: | United States: Food and Drug Administration |
|
Heparin Extracorporeal Low Density Lipo-Protein (LDL) Cholesterol Apheresis Device |
|
Hypercholesterolemia Hyperlipidemias Dyslipidemias Lipid Metabolism Disorders Metabolic Diseases Clotrimazole Miconazole Anti-Infective Agents, Local |
Anti-Infective Agents Therapeutic Uses Pharmacologic Actions 14-alpha Demethylase Inhibitors Enzyme Inhibitors Molecular Mechanisms of Pharmacological Action Antifungal Agents |