Correlation of Donor-specific Anti-endothelial Cells

This study is ongoing, but not recruiting participants.
Sponsor:
Information provided by (Responsible Party):
John Friedewald, Northwestern University
ClinicalTrials.gov Identifier:
NCT01545713
First received: March 1, 2012
Last updated: April 30, 2013
Last verified: April 2013
  Purpose

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor HLA antigens. Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.

Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.

XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.

This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation the investigators would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.


Condition
Living-Donor Kidney Transplants

Study Type: Observational
Study Design: Observational Model: Case-Only
Time Perspective: Prospective
Official Title: A Phase II, Prospective, Single-center Study: Correlation of Donor-specific Anti-precursor Endothelial Cells With Transplant Outcome for Recipients of Living-donor Kidney Transplants, Are Auto-antibodies Important.

Resource links provided by NLM:


Further study details as provided by Northwestern University:

Primary Outcome Measures:
  • To complete additional testing for accuracy [ Time Frame: June 2011 - February 2012 ] [ Designated as safety issue: No ]
    The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.


Secondary Outcome Measures:
  • To assess the frequency of autologous antibodies. [ Time Frame: June 2011 - February 2012 ] [ Designated as safety issue: No ]
    To assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.


Biospecimen Retention:   Samples Without DNA

A total of 40 cc/3 tablespoons of blood will be drawn once.


Estimated Enrollment: 50
Study Start Date: June 2011
Estimated Study Completion Date: May 2014
Primary Completion Date: February 2012 (Final data collection date for primary outcome measure)
Groups/Cohorts
Renal Transplant Recipients
Patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result.

  Hide Detailed Description

Detailed Description:

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor HLA antigens. Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.

Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.

XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.

This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation we would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.

Initial data from our laboratory indicates that the antigens identified by the XM-One Absorber® assay differ from the HLA antigens usually identified by routine cross match assays. Moreover, we were able to document that this is a polymorphic system and therefore identifying a donor-specific source is critical.

Of the 150 patients already studied under NU research protocol STU#00029988 we found that 19 patients exhibited a positive response in a donor-specific XM-One AbSorber® assay. In this current research protocol study we want to follow-up on the specimens that exhibited a positive response in a donor-specific XM-One AbSorber® assay and perform an autologous XM-One AbSorber® assay to validate the clinical significance of our results.

There has been one multicenter study reported indicating the "XM-One AbSorber® is a quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte cross matches" The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.

The secondary objective is to assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.

In this prospective study we plan to include all XM-One AbSorber® positive test results from all recipients of living-donor kidney transplants performed at Northwestern Memorial Hospital (NMH) since May 19, 2010 initial IRB approval until 250 transplants are performed. For this research protocol we will be targeting patients to consent only these individuals who have received a XM-One AbSorber® positive test result.

Each donor / recipient pair are required to send peripheral blood samples to the HLA laboratory prior to the scheduled transplant in order to perform lymphocyte cross match (to detect donor specific HLA antibodies; this is (SOC) standard of care). Left over serum and cells from these tests are being used to isolate an enriched precursor endothelial cell population and perform the XM-One AbSorber® assay (NU research protocol #STU00029988).

XM-One AbSorber® assay results - both autologous and allogeneic - will be captured and compared with graft outcome measurements at 3, 6, and 12 months post-transplant. Transplant outcome will be recorded as creatinine levels at the specific time points, protocol and for-cause biopsy results within the first year post transplant, diagnosis of acute cellular or humoral rejection, variation in immunosuppression levels, and any other complications.

Patients that exhibit a positive XM-One AbSorber® allogeneic cross match result will be requested to donate 4 green top tubes of peripheral blood. Cells obtained from this blood will be used in an autologous XM-One AbSorber® cross match assay using the original serum sample used for the allogeneic XM-One AbSorber® cross match assay.

  Eligibility

Ages Eligible for Study:   18 Years and older
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   No
Sampling Method:   Probability Sample
Study Population

Living-Donor kidney transplant recipients at Northwestern Memorial Hospital 18 year of age or older.

Criteria

Inclusion Criteria:

  1. patients older than 18 years of age
  2. patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result

Exclusion Criteria:

  1. patients undergoing deceased donor kidney transplant
  2. patients younger than 18 years of age
  Contacts and Locations
Please refer to this study by its ClinicalTrials.gov identifier: NCT01545713

Locations
United States, Illinois
Northwestern Memorial Hospital
Chicago, Illinois, United States, 60611
Sponsors and Collaborators
Northwestern University
Investigators
Principal Investigator: John Friedewald, MD Northwestern University
  More Information

No publications provided

Responsible Party: John Friedewald, Associate Professor of Medicine and Surgery, Northwestern University
ClinicalTrials.gov Identifier: NCT01545713     History of Changes
Other Study ID Numbers: XM-One AbSorber
Study First Received: March 1, 2012
Last Updated: April 30, 2013
Health Authority: United States: Institutional Review Board

Keywords provided by Northwestern University:
renal
kidney
transplant
living donor

ClinicalTrials.gov processed this record on June 18, 2013