Randomised Controlled Trial of Intubation, Comparing Pentax AWS Against Macintosh Laryngoscope. (PAWS)

The recruitment status of this study is unknown because the information has not been verified recently.
Verified December 2011 by NHS Grampian.
Recruitment status was  Not yet recruiting
Sponsor:
Collaborators:
Research and Development Department, NHS Grampian
University of Aberdeen
Information provided by (Responsible Party):
Lewis Walker, NHS Grampian
ClinicalTrials.gov Identifier:
NCT01029756
First received: December 9, 2009
Last updated: December 15, 2011
Last verified: December 2011
  Purpose

A randomised controlled trial of intubation by inexperienced anaesthetists, comparing the The Pentax Airway Scope AWS-S100 Rigid Video Laryngoscope(Pentax AWS) and the Macintosh Laryngoscope.


Condition Intervention
Anaesthesia
Airway Management
Videolaryngoscopy
Device: Macintosh Laryngoscope
Device: Pentax AWS Videolaryngoscope

Study Type: Interventional
Study Design: Allocation: Randomized
Endpoint Classification: Safety/Efficacy Study
Intervention Model: Parallel Assignment
Masking: Open Label
Official Title: A Randomised Controlled Trial of Intubation by Inexperienced Anaesthetists, Comparing the The Pentax Airway Scope AWS-S100 Rigid Video Laryngoscope(Pentax AWS) and the Macintosh Laryngoscope.

Further study details as provided by NHS Grampian:

Primary Outcome Measures:
  • Is there a clinically significant difference in the time taken to successfully intubate the trachea? [ Time Frame: Following induction of anaesthesia ] [ Designated as safety issue: Yes ]

Secondary Outcome Measures:
  • Is there a difference in the Intubation Difficulty Score? [ Time Frame: Measured at intubation ] [ Designated as safety issue: Yes ]

Estimated Enrollment: 120
Study Start Date: January 2012
Estimated Study Completion Date: September 2012
Estimated Primary Completion Date: September 2012 (Final data collection date for primary outcome measure)
Arms Assigned Interventions
Active Comparator: Macintosh Laryngoscope Device: Macintosh Laryngoscope
Device used to gain a direct view of the vocal cords, to enable an endotracheal tube to be passed into the trachea at induction of anaesthesia.
Other Name: Direct laryngoscopy
Active Comparator: Pentax AWS Videolaryngoscope Device: Pentax AWS Videolaryngoscope
Self-contained video laryngoscope with an integral colour-viewing screen mounted on the handle. A camera at the tip transmits an indirect image, which obviates the need to obtain a direct view of the vocal cords, when passing an endotracheal tube on induction of anaesthesia.
Other Name: Videolaryngoscopy

  Hide Detailed Description

Detailed Description:

General anaesthesia often requires that the trachea be protected by intubation. This involves placement of a cuffed endotracheal tube into the trachea, after the onset of unconsciousness and muscle relaxation. Usually this requires the anaesthetist to obtain a direct view of the patient's vocal cords via the mouth, using a laryngoscope such as the Macintosh laryngoscope. The endotracheal tube is then guided through the vocal cords into the trachea.

Difficult or failed intubation, is a potentially serious and occasionally life threatening complication. This is the unexpected inability to place the endotracheal tube in the correct place. The commonest cause is a failure to achieve an adequate view of the vocal cords at laryngoscopy.

Failed or difficult intubation significantly delays establishment of a secure airway and therefore can lead to major morbidity from hypoxia and/or aspiration of gastric contents. Other morbidity can also ensue from delay to the procedure in emergency situations or airway trauma due the various devices used or the force required to secure intubation. Whilst all anaesthetists and their assistants are trained to deal with difficult or failed intubations, disasters do occur. For example, in obstetrics, the previous Confidential Enquiry into Maternal Deaths reported five of the six deaths directly due to anaesthesia were related to intubation difficulties.

The Pentax Airway Scope AWS-S100 (Pentax AWS), Rigid Video Laryngoscope for Intubation is a new self-contained video laryngoscope with an integral colour-viewing screen mounted on the handle. A camera at the tip transmits an indirect image, which obviates the need to obtain a direct view of the vocal cords. It requires no prior set-up of equipment and is intuitive to use for anyone already competent in traditional direct laryngoscopy. Previously conducted evaluations of the scope have been presented and show that intubation can be secured within a clinically normal time span by various grades of anaesthetists in various clinical situations. Authors are currently suggesting it has a role as a back-up device for difficult intubations and for training. One has been obtained for the Foresterhill site for these purposes.

RATIONALE The simplicity of use and intuitive function of the Pentax AWS suggests it may have a wider role than as a back-up and could possibly be the first-line laryngoscope for situations where difficulty with intubation is more likely or more hazardous.

The incidence of difficult or failed intubation for an individual anaesthetist is related to their experience, decreasing as experience increases.

The purpose of this trial is to evaluate the Pentax AWS when used by relatively inexperienced anaesthetists. Inexperienced anaesthetists are those most likely to encounter difficulties and thus their practice carries the highest risk. Therefore, this is a setting in which there would be a particular benefit to patient safety in having the most effective tool for successful and timely completion of tracheal intubation.

METHODS The study will compare intubation using the Pentax AWS vs. the usual Macintosh laryngoscope in a sample of patients where 1st and 2nd year specialist trainees in anaesthesia (ST's) perform the intubation. There will be no other change in routine practice for the purposes of the trial. Specifically, the trial will recruit only from the population of patients that the ST's are routinely scheduled to intubate anyway. They will be working under the direct supervision of a consultant or senior specialist registrar (SpR), at all times.

Initially, data relating to routine intubations with the Macintosh laryngoscope will be collected. We will conduct training in the method of use of the Pentax AWS with the ST's, to a pre-determined level (see below) and collect and compare learning data, during routine clinical work with this laryngoscope. Following on from this, we will determine the effectiveness of the Pentax AWS in patients undergoing routine tracheal intubation.

4 ST's will perform the intubations within the trial. They fulfil the experience criteria required of the study, they began anaesthetic training between August 2010 and August 2011, have reached the required Royal College of Anaesthetists' level of competency in the practice of intubation and are approved to anaesthetise with indirect supervision.

Prior to commencement of recruitment into this study, it will be necessary for these ST anaesthetists to demonstrate a safe level of ability with the Pentax AWS. This is in order not to compromise safety in those patients randomized to undergo intubation with the Pentax AWS. They will be trained in the use of the Pentax AWS by the principle investigator (PI), initially using an airway training manikin and then in normal clinical practice. After gaining basic skill with the Pentax AWS, intubation with this scope will be timed. Supervised training with the Pentax AWS will continue until the ST anaesthetist is able to intubate in a clinically safe timeframe and then ST anaesthetists will be required to perform this successfully without trainer input in ten consecutive procedures. Once assessed as competent with the Pentax AWS by the PI they will be eligible to intubate patients entering the trial.

  Eligibility

Ages Eligible for Study:   18 Years and older
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   Yes
Criteria

Inclusion Criteria:

  • Adults (18 years and over)
  • scheduled for elective surgery whose anaesthetic plan would normally include oral intubation using a Macintosh laryngoscope blade by a junior anaesthetist and who have given valid informed consent.

Exclusion Criteria:

  • Patients requiring special techniques for intubation such as awake fibreoptic intubation.
  • Unconscious or critically ill patients.
  • Emergency situations.
  • Vulnerable patients including patients with:

    • learning difficulties,
    • terminal illness, mental illness, dementia,
    • prisoners and
    • those who could be considered to have a particularly dependent relationship with the investigator(such as medical students).
  Contacts and Locations
Please refer to this study by its ClinicalTrials.gov identifier: NCT01029756

Contacts
Contact: Lewis Walker, MBChB, FRCA 01224553144 lewis.walker@nhs.net
Contact: Robert A Lendrum, MBChB, FRCA 01224553142 rlendrum@nhs.net

Locations
United Kingdom
Aberdeen Royal Infirmary Not yet recruiting
Aberdeen, Grampian, United Kingdom, AB25 2ZN
Contact: Lewis Walker, MBChB, FRCA    01224553144    lewis.walker@nhs.net   
Contact: Robert A Lendrum, MBChB, FRCA    01224553142    rlendrum@nhs.net   
Sponsors and Collaborators
NHS Grampian
Research and Development Department, NHS Grampian
University of Aberdeen
Investigators
Principal Investigator: Lewis Walker, MBChB,FRCA Consultant Anaesthetist NHS Grampian
  More Information

No publications provided

Responsible Party: Lewis Walker, Dr, NHS Grampian
ClinicalTrials.gov Identifier: NCT01029756     History of Changes
Other Study ID Numbers: ARI PentaxAWS 10
Study First Received: December 9, 2009
Last Updated: December 15, 2011
Health Authority: United Kingdom: Research Ethics Committee

Keywords provided by NHS Grampian:
Pentax Airway Scope AWS S100
Pentax AWS
Macintosh
Laryngoscope
Video Laryngoscope

ClinicalTrials.gov processed this record on April 17, 2014