Leadless Electrocardiogram (ECG) Evaluation Study (LECG)
| Tracking Information | |||||
|---|---|---|---|---|---|
| First Received Date ICMJE | February 3, 2011 | ||||
| Last Updated Date | November 14, 2011 | ||||
| Start Date ICMJE | July 2010 | ||||
| Estimated Primary Completion Date | December 2011 (final data collection date for primary outcome measure) | ||||
| Current Primary Outcome Measures ICMJE |
Proportion of patients with LECG performing clinically equivalent to PECG during standard pacemaker follow-up procedure. [ Time Frame: 30 to 120 days ] [ Designated as safety issue: No ] During CRT-P standard follow-up, ECG is used to determine atrial, left and right ventricular pacing thresholds. As primary endpoint, we will consider the proportion of patients for which for all leads LECG provides pacing threshold values that are clinically equivalent to those obtained with PECG taken as reference. The analysis will be performed on data collected at the 1-Month Follow-Up visit when the device pocket healing process is completed. Clinical equivalence will be defined as the LECG threshold values being no more than 0.5 volts different from the PECG threshold values. |
||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||
| Change History | Complete list of historical versions of study NCT01297283 on ClinicalTrials.gov Archive Site | ||||
| Current Secondary Outcome Measures ICMJE |
|
||||
| Original Secondary Outcome Measures ICMJE | Same as current | ||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||
| Descriptive Information | |||||
| Brief Title ICMJE | Leadless Electrocardiogram (ECG) Evaluation Study | ||||
| Official Title ICMJE | Leadless ECG Evaluation Study | ||||
| Brief Summary | The leadless electrocardiogram (LECG) is a new technology incorporated into the Consulta CRT-P to obtain an ECG signal from the Consulta CRT-P similar to a surface ECG obtained from the device programmer (PECG) or an external ECG machine. The purpose of the study is to obtain more data on leadless ECG to determine whether LECG during standard CRT follow-up can indeed adequately replace surface ECG and to evaluate if it can be used during remote follow-up evaluations. |
||||
| Detailed Description | The leadless electrocardiogram (LECG) is a new technology incorporated into the Consulta CRT-P to obtain an ECG signal from the Consulta CRT-P similar to a surface ECG obtained from the device programmer (PECG) or an external ECG machine. The LECG signals are measured from three electrodes mounted on the outside of the pacemaker housing and provides an electrical far field signal of the electrical activity of the heart. The LECG provides three ECG channels as different projections of the electrical activity of the heart, similar to the surface ECG. Clinical interest of LECG is threefold. First, ECG recordings are routinely used to perform pacemaker and cardiac resynchronization systems in-office follow-up mainly to determine pacing thresholds. Connection of ECG electrodes to the patient as well as the time needed to acquire an acceptable ECG signal during routine follow-up could be saved using LECG which would make follow-up easier and less time consuming. Secondly, connecting ECG electrodes requires the patient to be present at the clinic for the follow-up. Use of LECG in conjunction with a transmitting system will allow remote patient follow-up. In that case, correct ventricular capture confirmation by the LECG is of key importance. Finally, LECG stored in device memory at the time of an arrhythmia episode occurrence, can help better classify it. The following factors might influence the quality of the LECG and/or the axis of the LECG:
|
||||
| Study Type ICMJE | Interventional | ||||
| Study Phase | Phase 4 | ||||
| Study Design ICMJE | Allocation: Randomized Endpoint Classification: Efficacy Study Intervention Model: Crossover Assignment Masking: Open Label Primary Purpose: Supportive Care |
||||
| Condition ICMJE | Heart Failure | ||||
| Intervention ICMJE |
|
||||
| Study Arm (s) |
|
||||
| Publications * | Not Provided | ||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||
| Recruitment Information | |||||
| Recruitment Status ICMJE | Active, not recruiting | ||||
| Estimated Enrollment ICMJE | 200 | ||||
| Estimated Completion Date | January 2012 | ||||
| Estimated Primary Completion Date | December 2011 (final data collection date for primary outcome measure) | ||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||
| Gender | Both | ||||
| Ages | 18 Years and older | ||||
| Accepts Healthy Volunteers | No | ||||
| Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | ||||
| Location Countries ICMJE | France | ||||
| Administrative Information | |||||
| NCT Number ICMJE | NCT01297283 | ||||
| Other Study ID Numbers ICMJE | Leadless ECG Evaluation Study | ||||
| Has Data Monitoring Committee | No | ||||
| Responsible Party | HIDDEN-LUCET Françoise, M.D., Hôpital de La Pitié Salpêtrière, Paris | ||||
| Study Sponsor ICMJE | Medtronic Bakken Research Center | ||||
| Collaborators ICMJE | Not Provided | ||||
| Investigators ICMJE |
|
||||
| Information Provided By | Medtronic Bakken Research Center | ||||
| Verification Date | November 2011 | ||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||