Clinical Effectiveness of In-office Bleaching Activated With a LED/Laser Device
| Tracking Information | |||||
|---|---|---|---|---|---|
| First Received Date ICMJE | October 28, 2010 | ||||
| Last Updated Date | December 5, 2011 | ||||
| Start Date ICMJE | January 2011 | ||||
| Primary Completion Date | September 2011 (final data collection date for primary outcome measure) | ||||
| Current Primary Outcome Measures ICMJE |
Change in color [ Time Frame: at the 2-week recall ] [ Designated as safety issue: No ] The change in color will be measured using Vita Shade Classical scale at baseline and after the end of the bleaching protocol. A spectrophootometer Easy Shade will also be used and the coordinates of the CIELab system will be recorded. |
||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||
| Change History | Complete list of historical versions of study NCT01231243 on ClinicalTrials.gov Archive Site | ||||
| Current Secondary Outcome Measures ICMJE |
Prevalence and intensity of tooth sensitivity [ Time Frame: 24-hours after the bleaching ] [ Designated as safety issue: Yes ] The visual analog scale will be used for patients to record their tooth sensitivity in a 0 to 10 scale. |
||||
| Original Secondary Outcome Measures ICMJE | Same as current | ||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||
| Descriptive Information | |||||
| Brief Title ICMJE | Clinical Effectiveness of In-office Bleaching Activated With a LED/Laser Device | ||||
| Official Title ICMJE | Color Change and Sensitivity Level for In-office Bleaching With and Without a LED/Laser Device | ||||
| Brief Summary | There is a controversy in the dentistry literature about how the use of associated light to activate 35% hydrogen peroxide gel during in-office tooth bleaching may increase the bleaching effectiveness. The studies that demonstrated an increased level of bleaching using light activation employed lower hydrogen peroxide gels while the ones reporting no statistical difference employed higher hydrogen peroxide gels. The hypothesis of this study is that the effectiveness of light activation tooth bleaching in dependent on the hydrogen peroxide concentration employed. |
||||
| Detailed Description | The aim of this study is to compare the color change and tooth sensitivity of in-office bleaching using different hydrogen peroxide concentrations and with or without light activation. Sixty patients will be enrolled in this trial and divide equally into 4 groups according to the combination of the main factors hydrogen peroxide concentration (35% or 20%) or LED/laser activation (yes or no). Three 15-min applications will be performed in each clinical appointment. A LED/laser device will be used in the respective groups for three 1-min application with an interval of 2 min. The same procedure will be repeated one week later. The color change will be assessed after hte 1st and 2nd session, after 1 week and 6 months of the end of the treatment using a value-oriented shade Vita Classical and a spectrophotometer Easy Shade. The tooth sensitivity will be reported by patients using a 0 to 10 visual analog scale. The Student t test (α = .05) will be used to compare the tooth color changes and the intensity of tooth sensitivity between groups at baseline and immediately after the first and second bleaching appointments. The Fisher exact test and Student t test (α = .05), respectively, will be used to analyze the percentage of patients with tooth sensitivity and its intensity. |
||||
| Study Type ICMJE | Interventional | ||||
| Study Phase | Phase 4 | ||||
| Study Design ICMJE | Allocation: Randomized Endpoint Classification: Safety/Efficacy Study Intervention Model: Parallel Assignment Masking: Single Blind (Outcomes Assessor) Primary Purpose: Supportive Care |
||||
| Condition ICMJE | Tooth Discoloration | ||||
| Intervention ICMJE | Procedure: in-office bleaching with/without light
Two clinical sessions of tooth bleaching will be performed in each patient with a 1-week interval between them. In each session, three 15-min applications of the gel will be done using one of the two concentrations under investigation. In half of the sample of each concentration, the gel will be activated with a LED/laser device for a total of 3 min, as specified by the DMC manufacturer.
Other Names:
|
||||
| Study Arm (s) |
|
||||
| Publications * | Not Provided | ||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||
| Recruitment Information | |||||
| Recruitment Status ICMJE | Completed | ||||
| Enrollment ICMJE | 60 | ||||
| Completion Date | September 2011 | ||||
| Primary Completion Date | September 2011 (final data collection date for primary outcome measure) | ||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||
| Gender | Both | ||||
| Ages | 18 Years to 30 Years | ||||
| Accepts Healthy Volunteers | Yes | ||||
| Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | ||||
| Location Countries ICMJE | Brazil | ||||
| Administrative Information | |||||
| NCT Number ICMJE | NCT01231243 | ||||
| Other Study ID Numbers ICMJE | ARAL001 | ||||
| Has Data Monitoring Committee | No | ||||
| Responsible Party | Alessandra Reis, Universidade Estadual de Ponta Grossa | ||||
| Study Sponsor ICMJE | Universidade Estadual de Ponta Grossa | ||||
| Collaborators ICMJE | Not Provided | ||||
| Investigators ICMJE |
|
||||
| Information Provided By | Universidade Estadual de Ponta Grossa | ||||
| Verification Date | December 2011 | ||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||