The Purpose of the Study is to Evaluate Whether the Use of C-Pulse™ as Treatment for Patients in Moderate to Severe Heart Failure (HF) is Associated With Reasonable Assurance of Safety and Performance
| Tracking Information | |||||
|---|---|---|---|---|---|
| First Received Date ICMJE | August 4, 2010 | ||||
| Last Updated Date | July 12, 2012 | ||||
| Start Date ICMJE | March 2010 | ||||
| Estimated Primary Completion Date | March 2013 (final data collection date for primary outcome measure) | ||||
| Current Primary Outcome Measures ICMJE |
|
||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||
| Change History | Complete list of historical versions of study NCT01176370 on ClinicalTrials.gov Archive Site | ||||
| Current Secondary Outcome Measures ICMJE |
|
||||
| Original Secondary Outcome Measures ICMJE | Same as current | ||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||
| Descriptive Information | |||||
| Brief Title ICMJE | The Purpose of the Study is to Evaluate Whether the Use of C-Pulse™ as Treatment for Patients in Moderate to Severe Heart Failure (HF) is Associated With Reasonable Assurance of Safety and Performance | ||||
| Official Title ICMJE | A Prospective Study to Assess the Safety and Indications of Performance of the C-Pulse™ System in Relieving Heart Failure Symptoms in Patients With ACC/AHA Stage C, NYHA Class III-ambulatory Class IV Heart Failure. | ||||
| Brief Summary | The C-Pulse Study is evaluating the safety and performance of a new product for the treatment of heart failure. The product is designed to help reduce the symptoms of heart failure and help patients function better with daily activities. The study evaluates multiple measures of heart function and whether the patient's quality of life has been improved since the device implant. The patient will have several visits after the device implant to assess how well they are doing and to monitor any safety concerns. |
||||
| Detailed Description | Sunshine Heart Inc. is sponsoring a prospective trial to assess the safety and provide indications for performance of the Sunshine Heart C-PulseTM System ("C-Pulse™"). The current need is for a counterpulsation device or method that is effective enough to make its application appealing as a long-term implant to a large number of patients and physicians. It must be simple and safe, with a straight-forward implant procedure, and with long-term measurable patient benefits. Further, it would be advantageous for the counterpulsation device to be smaller, easier to insert, ambulatory, disconnectable, and not in the bloodstream. Such a device may be more readily adopted by a wider group of cardiologists and surgeons, and be suitable for a wider group of people in NYHA Class III or IV heart failure. It is important to point out that a counterpulsation device is aimed to augment native heart function and is fundamentally different from total artificial hearts, left ventricular assist devices and heart transplants which are meant to be a total replacement or an alternative to the native heart. Thus, the counterpulsation device is considered non-obligatory and not life-supporting. Sunshine Heart, Inc has proposed C-Pulse™, a novel ambulatory, non-obligatory, non-blood contacting extra-ascending aortic counterpulsation system. The C-Pulse™ System is designed to be implanted without the need for cardiopulmonary bypass or extensive dissection, to be able to be activated immediately, to augment heart function in a safe manner and to provide sustained relief from heart failure symptoms. It can be turned off safely, and similarly, in failure modes, is considered to have an associated low risk of death or disability, other than the recurrence of heart failure symptoms. C-Pulse™ is not an alternative to the heart, it is an augmentation device, and it does not preclude the use of therapies that provide full circulatory support such as heart transplantation or LVADs. The C-Pulse™ System consists of a counterpulsation Cuff secured around the outside of the ascending aorta, the main blood vessel out of the heart. The Cuff and a heart signal sensing wire are attached to an external driver. The external Driver inflates and deflates the Cuff in sequence with the ECG signal to assist heart function and improve the pumping capacity of the heart. The Cuff deflects the aorta in a "thumb-printing" manner which has been optimized to minimize aortic wall strain and maximize blood volume displacement per beat. The C-Pulse™ System is non-blood contacting, simple to insert, and can be turned on and off as required; all natural blood pathways are maintained - there is no exposure of foreign material to the bloodstream. |
||||
| Study Type ICMJE | Interventional | ||||
| Study Phase | Phase 1 | ||||
| Study Design ICMJE | Endpoint Classification: Safety/Efficacy Study Intervention Model: Single Group Assignment Masking: Open Label Primary Purpose: Treatment |
||||
| Condition ICMJE | Heart Failure | ||||
| Intervention ICMJE |
|
||||
| Study Arm (s) | Experimental: Implantable Counterpulsation Therapy
The study is a single arm study with up to 20 patients enrolled and implanted with implantable counterpulsation. Patients that meet eligibility will be enrolled and implanted into the treatment arm of the study. There is not a control arm in this feasibility study.
Interventions:
|
||||
| Publications * | Not Provided | ||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||
| Recruitment Information | |||||
| Recruitment Status ICMJE | Recruiting | ||||
| Estimated Enrollment ICMJE | 20 | ||||
| Estimated Completion Date | October 2013 | ||||
| Estimated Primary Completion Date | March 2013 (final data collection date for primary outcome measure) | ||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||
| Gender | Both | ||||
| Ages | 18 Years to 75 Years | ||||
| Accepts Healthy Volunteers | No | ||||
| Contacts ICMJE |
|
||||
| Location Countries ICMJE | Canada | ||||
| Administrative Information | |||||
| NCT Number ICMJE | NCT01176370 | ||||
| Other Study ID Numbers ICMJE | PRO 02977 Rev - A | ||||
| Has Data Monitoring Committee | Yes | ||||
| Responsible Party | Sunshine Heart Inc. | ||||
| Study Sponsor ICMJE | Sunshine Heart Inc. | ||||
| Collaborators ICMJE | Not Provided | ||||
| Investigators ICMJE |
|
||||
| Information Provided By | Sunshine Heart Inc. | ||||
| Verification Date | July 2012 | ||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||