Use of Interventional MRI for Implantation of Deep Brain Stimulator Electrodes (iMRI)
| Tracking Information | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| First Received Date ICMJE | November 14, 2008 | ||||||||||||||||
| Last Updated Date | May 16, 2013 | ||||||||||||||||
| Start Date ICMJE | July 2003 | ||||||||||||||||
| Estimated Primary Completion Date | July 2017 (final data collection date for primary outcome measure) | ||||||||||||||||
| Current Primary Outcome Measures ICMJE |
|
||||||||||||||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||||||||||||||
| Change History | Complete list of historical versions of study NCT00792532 on ClinicalTrials.gov Archive Site | ||||||||||||||||
| Current Secondary Outcome Measures ICMJE | Not Provided | ||||||||||||||||
| Original Secondary Outcome Measures ICMJE | Not Provided | ||||||||||||||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||||||||||||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||||||||||||||
| Descriptive Information | |||||||||||||||||
| Brief Title ICMJE | Use of Interventional MRI for Implantation of Deep Brain Stimulator Electrodes | ||||||||||||||||
| Official Title ICMJE | Use of Interventional MRI for Implantation of Deep Brain Stimulator Electrodes | ||||||||||||||||
| Brief Summary | The purpose of this study is to determine the safety and effectiveness of a new procedure for placing DBS electrodes, in which the entire surgery is performed within an MRI scanner ("interventional MRI"), with the patient fully asleep (under general anesthesia). The standard method for the placement of deep brain stimulators does not use MRI during the actual DBS placement. The standard method involves placement of a rigid frame on the patient's head, performance of a short MRI scan, transport to the operating room, placement of the DBS electrodes in the operating room, and return to the MRI suite for another MR to confirm correct electrode placement. In the standard method, the patient must be awake for 2-4 hours in the operating room to have "brain mapping" performed, where the brain target is confirmed by passing "microelectrodes" (thin wires) into the brain to record its electrical activity. In the standard method, general anesthesia is not required. In this study, the surgery is guided entirely by MRI images performed multiple times as the DBS electrode is advanced. This eliminates the need for the patient to be awake, and eliminates the need for passing microelectrodes into the brain before placing the permanent DBS electrode. |
||||||||||||||||
| Detailed Description | Deep brain stimulation (DBS) is a new but increasingly common surgical technique for the treatment of Parkinson's disease and dystonia. The current technical approach to DBS implantation involves frame-based stereotaxy. In this method, a stereotactic frame is rigidly fixed to the patient's skull, an MRI is obtained, an anatomic target is identified, and the coordinates of the target in stereotactic space are calculated. Instruments are mounted on the stereotactic frame that point to the calculated coordinate. However, due to the inherent inaccuracies in standard frame-based stereotaxy, a complex 6-hour procedure then ensues to "map" the brain target with microelectrodes, place the lead, and return to the MR unit to confirm proper placement. The goal of this project is to test the feasibility of performing DBS implantation entirely within the Phillips 1.5T open magnet MRI machine. Prior to study initiation, instrumentation and MR protocols were tested using a phantom head. In the proposed project, subthalamic nucleus or Globus Pallidus DBS implantations will be performed bilaterally in patients with Parkinson's disease or dystonia. Patients will be under general anesthesia. Targeting and lead verification are performed with imaging alone, without physiologic mapping. Data is to be gathered on the following: Operative time, degree of benefit with bilateral implantation (changes in standard rating scales of motor disability), DBS voltage requirements, complications), and electrode location by MR. These measures will be compared with our historical controls, previously entered into our research database, in which electrodes were placed by the standard methods. We expect that the use of near real time MR will improve the speed and accuracy of DBS implantation, and eliminate the need for invasive physiological monitoring. |
||||||||||||||||
| Study Type ICMJE | Interventional | ||||||||||||||||
| Study Phase | Phase 4 | ||||||||||||||||
| Study Design ICMJE | Endpoint Classification: Safety/Efficacy Study Intervention Model: Single Group Assignment Masking: Open Label Primary Purpose: Treatment |
||||||||||||||||
| Condition ICMJE |
|
||||||||||||||||
| Intervention ICMJE |
|
||||||||||||||||
| Study Arm (s) | Experimental: iMRI
Interventions:
|
||||||||||||||||
| Publications * | Martin AJ, Larson PS, Ostrem JL, Keith Sootsman W, Talke P, Weber OM, Levesque N, Myers J, Starr PA. Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging. Magn Reson Med. 2005 Nov;54(5):1107-14. | ||||||||||||||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||||||||||||||
| Recruitment Information | |||||||||||||||||
| Recruitment Status ICMJE | Recruiting | ||||||||||||||||
| Estimated Enrollment ICMJE | 100 | ||||||||||||||||
| Estimated Completion Date | July 2018 | ||||||||||||||||
| Estimated Primary Completion Date | July 2017 (final data collection date for primary outcome measure) | ||||||||||||||||
| Eligibility Criteria ICMJE | Parkinson's Disease Inclusion Criteria:
Exclusion Criteria:
Dystonia Inclusion Criteria
Exclusion Criteria
|
||||||||||||||||
| Gender | Both | ||||||||||||||||
| Ages | 6 Years and older | ||||||||||||||||
| Accepts Healthy Volunteers | No | ||||||||||||||||
| Contacts ICMJE | Not Provided | ||||||||||||||||
| Location Countries ICMJE | United States | ||||||||||||||||
| Administrative Information | |||||||||||||||||
| NCT Number ICMJE | NCT00792532 | ||||||||||||||||
| Other Study ID Numbers ICMJE | iMRI, R21EB008888 | ||||||||||||||||
| Has Data Monitoring Committee | No | ||||||||||||||||
| Responsible Party | University of California, San Francisco | ||||||||||||||||
| Study Sponsor ICMJE | University of California, San Francisco | ||||||||||||||||
| Collaborators ICMJE |
|
||||||||||||||||
| Investigators ICMJE |
|
||||||||||||||||
| Information Provided By | University of California, San Francisco | ||||||||||||||||
| Verification Date | May 2013 | ||||||||||||||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||||||||||||||