Reliability of Point-of-care INR Measurements in Patients With Antiphospholipid-antibody Syndrome Treated With Warfarin
- Full Text View
- Tabular View
- No Study Results Posted
- Disclaimer
- How to Read a Study Record
Purpose
The antiphospholipid-antibody syndrome (APLA), which includes lupus anticoagulant, anticardiolipin, and anti-beta-2-glycoproteinI antibodies, is a thrombophilic disorder associated with arterial thrombosis, venous thrombosis or both. Patients diagnosed with APLA have a higher risk of recurrent thrombosis than do patients without known antibodies. Currently, warfarin is considered the anticoagulant of choice for prophylactic antithrombotic treatment for APLA patients after their first episode of thrombosis. In some patients with APLA who are treated with warfarin, the INR values determined on plasma are unreliable due to an influence of the APLA on the INR. In these individuals, alternative monitoring methods, such as factor II activity, chromogenic factor X activity or prothrombin-proconvertin time should be used to assess adequate anticoagulation. These tests are expensive and not widely available to some clinicians. Point-of-care (POC) instruments, on the other hand, are readily accessible to clinicians. Previous research has shown that INR values from 3 older point-of-care (POC) instruments are unreliable in 1/3 of APLA patients (CoaguChekTM, ProTimeTM, INRatioTM). However, there are now newer versions of these POC instruments available (CoaguChek XSTM, an investigational ProTime device, and a newer INRatioTM device) and it is unknown if these newer POC instruments are reliable in patients with APLA. The purpose of this study is to determine whether newer POC instruments are reliable in patients with APLA.
| Condition | Intervention |
|---|---|
|
Antiphospholipid Syndrome |
Device: INR by point-of-care instruments and venopuncture |
| Study Type: | Observational |
| Study Design: | Observational Model: Case Control Time Perspective: Prospective |
| Official Title: | INR Determined by Plasma-based Methods Versus Newer Point-of-care Instruments in Patients With Antiphospholipid-antibody Syndrome Treated With Anticoagulants |
| Enrollment: | 63 |
| Study Start Date: | March 2009 |
| Study Completion Date: | May 2009 |
| Primary Completion Date: | May 2009 (Final data collection date for primary outcome measure) |
| Groups/Cohorts | Assigned Interventions |
|---|---|
|
APLA
Patients with antiphospholipid antibody syndrome.
|
Device: INR by point-of-care instruments and venopuncture
Three fingersticks will be performed and from each one drop of capillary or venous whole blood collected from a fingerstick performed by the primary investigator to measure PT/INR using the CoaguChekXSTM (10 microliters), ProTimeTM (27 microliters), the investigational ProTime, and INRatioTM 15 microliters) point-of-care instruments and one i.v. blood draw (20 mL of blood) will be performed by a phlebotomist.
|
|
Control
Patients on warfarin therapy but without antiphosphilipid antibody syndrome.
|
Device: INR by point-of-care instruments and venopuncture
Three fingersticks will be performed and from each one drop of capillary or venous whole blood collected from a fingerstick performed by the primary investigator to measure PT/INR using the CoaguChekXSTM (10 microliters), ProTimeTM (27 microliters), the investigational ProTime, and INRatioTM 15 microliters) point-of-care instruments and one i.v. blood draw (20 mL of blood) will be performed by a phlebotomist.
|
Eligibility| Ages Eligible for Study: | 18 Years and older |
| Genders Eligible for Study: | Both |
| Accepts Healthy Volunteers: | No |
| Sampling Method: | Non-Probability Sample |
APLA patients will be identified through the UNC Thrombophilia Program database. Control patients will be recruited at UNC Anticoagulation Clinic visits.
APLA Inclusion Criteria:
- Prolongation of a phospholipid-dependent screening assay, 2) lack of correction of a prolonged screening assay after a 1:1 mix with pooled normal plasma, and 3) correction of a prolonged screening assay by the addition of excess phospholipid. Two positive lupus anticoagulant confirmations at least 3 months apart will be required.
- Diagnosis of anticardiolipin antibodies defined as elevated levels of ACA-IgG (>30) and/or ACA-IgM (>15) on two separate occasions at least 3 months apart.
- Stable warfarin therapy, defined as the maintenance of a warfarin dose for a minimal of 2 weeks regardless of INR.
APLA Exclusion Criteria:
- Patients whose warfarin dose has changed within the past 2 weeks.
Control Inclusion Criteria:
- No evidence of either a positive LA or ACA diagnosis by confirmation of negative laboratory values and/or documentation of no clinical signs and symptoms concurrent with these conditions.
- Stable warfarin therapy, defined as the maintenance of a warfarin dose for a minimal of 2 weeks regardless of INR.
Control Exclusion Criteria:
- Patients whose warfarin dose has changed within the past 2 weeks.
Contacts and Locations| United States, North Carolina | |
| University of North Carolina at Chapel Hill | |
| Chapel Hill, North Carolina, United States, 27514 | |
| Principal Investigator: | Lauren B McKnight, PharmD | University of North Carolina, Chapel Hill |
More Information
No publications provided
| Responsible Party: | Lauren McKnight, PharmD, CPP, Clinical Pharmacist, University of North Carolina, Chapel Hill |
| ClinicalTrials.gov Identifier: | NCT00878137 History of Changes |
| Other Study ID Numbers: | POC Comparison 08-1883 |
| Study First Received: | April 6, 2009 |
| Last Updated: | October 12, 2012 |
| Health Authority: | United States: Institutional Review Board |
Additional relevant MeSH terms:
|
Antiphospholipid Syndrome Autoimmune Diseases Immune System Diseases Antibodies |
Antibodies, Antiphospholipid Immunologic Factors Physiological Effects of Drugs Pharmacologic Actions |
ClinicalTrials.gov processed this record on May 23, 2013